Connecting ZKTeco Devices

EasyTime uses the ADMS Push Protocol — devices connect outbound to the server (no port forwarding into the device needed).

Device Configuration

On the ZKTeco device menu:

  1. Go to Comm → Cloud Service (or ADMS settings)
  2. Set Server Address: http://YOUR_SERVER_IP/
  3. Set Port: 80 (or 443 for HTTPS)
  4. Set ADMS URL path: /iclock/cdata
  5. Enable Cloud Push / ADMS Push
  6. Save and reboot device

Verification

After configuration, the device should appear in EasyTime → Devices within 1–2 minutes with status Online.

Troubleshooting

  • Ensure the device can reach your server IP on port 80 (firewall rules)
  • Check device logs for connection errors
  • In EasyTime Devices page, the Last Seen time updates every heartbeat (30 sec)
  • Use Send Command → GET_INFO to query device firmware details